@@ -0,0 +1,143 @@
substitutions:
devicename: bathroom-switch-1
# Name for the relays
channel_1: Light
channel_2: Air
max_power: "2000.0" # watt
max_temp: "80.0" # °C
esphome:
name: ${devicename}
platform: ESP8266
board: esp01_1m
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
# Enable Home Assistant API
api:
i2c:
sda: GPIO12
scl: GPIO14
sensor:
- platform: ade7953_i2c
voltage:
name: ${devicename} voltage
current_a:
name: ${channel_2} current
internal: true
current_b:
name: ${channel_1} current
internal: true
active_power_a:
name: ${channel_2} power
id: power_channel_2
filters:
- multiply: 1
on_value_range:
- above: ${max_power}
then:
- output.turn_off: shelly_25_relay_2
- homeassistant.service:
service: persistent_notification.create
data:
title: Message from ${devicename}
data_template:
message: Switch turned off because power exceeded ${max_power}W
active_power_b:
name: ${channel_1} power
id: power_channel_1
filters:
- multiply: -1
on_value_range:
- above: ${max_power}
then:
- output.turn_off: shelly_25_relay_1
- homeassistant.service:
service: persistent_notification.create
data:
title: Message from ${devicename}
data_template:
message: Switch turned off because power exceeded ${max_power}W
update_interval: 30s
# NTC Temperature
- platform: ntc
sensor: temp_resistance_reading
name: ${devicename} temperature
unit_of_measurement: "°C"
accuracy_decimals: 1
icon: "mdi:thermometer"
calibration:
b_constant: 3350
reference_resistance: 10kOhm
reference_temperature: 298.15K
on_value_range:
- above: ${max_temp}
then:
- output.turn_off: shelly_25_relay_1
- output.turn_off: shelly_25_relay_2
- homeassistant.service:
service: persistent_notification.create
data:
title: Message from ${devicename}
data_template:
message: Switch turned off because temperature exceeded ${max_temp}°C
- platform: resistance
id: temp_resistance_reading
sensor: temp_analog_reading
configuration: DOWNSTREAM
resistor: 32kOhm
- platform: adc
id: temp_analog_reading
pin: A0
status_led:
pin:
number: GPIO0
inverted: yes
output:
- platform: gpio
pin: GPIO4
id: shelly_25_relay_1
- platform: gpio
pin: GPIO15
id: shelly_25_relay_2
light:
- platform: binary
name: "${channel_1}"
output: shelly_25_relay_1
id: lightid
- platform: binary
name: "${channel_2}"
output: shelly_25_relay_2
id: airid
binary_sensor:
- platform: gpio
pin:
number: GPIO13
name: "${channel_1} input"
internal: true
on_state:
then:
- light.toggle: lightid
- platform: gpio
pin:
number: GPIO5
name: "${channel_2} input"
internal: true
on_state:
then:
- light.toggle: airid
# Prevent short circuit with "floating" pin!
- platform: gpio
pin: GPIO16
name: "ade7953 IRQ pin"
internal: true